Cara Pasang Otomatis Pompa Air Dengan Kontaktor, Selector Switch dan Radar #pompaair
Summary
TLDRThis video tutorial demonstrates how to install an automatic water pump system using a radar, contactor, and selector switch. It covers both manual and automatic modes, ensuring the pump operates even if the automatic system fails. The process includes wiring the components, connecting the selector switch, setting up the radar for automatic operation, and testing both modes. The video emphasizes safety with the inclusion of an MCB and highlights troubleshooting steps, ensuring users can successfully set up and operate the pump. The tutorial concludes with a functional test of both manual and automatic modes.
Takeaways
- 😀 The video demonstrates how to install an automatic water pump system using Radar, a contactor, and a selector switch.
- 😀 The selector switch allows the system to operate in both manual and automatic modes, ensuring continued operation if automatic functionality fails.
- 😀 The system includes a contactor and an MCB (Miniature Circuit Breaker) for protection, along with the Radar Torrent for automation.
- 😀 The process starts by connecting the phase cable from the MCB input to the terminal block.
- 😀 A jumper is installed in the selector switch to divide the manual and automatic modes.
- 😀 The Radar is connected to terminals A1 and A2 for proper operation, with one cable from the Radar going to the selector switch and the other to the contactor coil.
- 😀 The manual mode wiring is set up so the pump can still operate in case the automatic system fails.
- 😀 Neutral cables from the contactor coil (A2) are connected to the terminal block and jumper cables are added for neutral connections.
- 😀 For the load connection, either a socket or direct wiring to the pump is used to complete the circuit.
- 😀 After wiring is complete, the system is tested first in manual mode, followed by the automatic mode with the Radar, to ensure both modes work as intended.
- 😀 The video concludes with a successful test of both manual and automatic modes, demonstrating that the system functions properly.
Q & A
What is the main purpose of the video?
-The main purpose of the video is to demonstrate the installation of an automatic water pump system using a Radar, contactor, and a selector switch.
Why is a selector switch used in this setup?
-A selector switch is used to allow the pump to operate both manually and automatically. This ensures that if the automatic system fails, the pump can still be operated manually.
What safety components are included in the setup?
-The setup includes a contactor, an MCB (Miniature Circuit Breaker), and a Radar Torrent for safety and to manage automatic operation.
How does the Radar function in this system?
-The Radar is used as part of the automatic control system to monitor and manage the operation of the water pump.
What is the role of the contactor in this installation?
-The contactor is responsible for controlling the power flow to the pump and enabling the automatic and manual operation modes.
How are the electrical wires connected to the selector switch?
-Wires are connected from the common terminal of the selector switch to both the manual and automatic outputs, enabling the selection of either mode.
What is the purpose of the jumper cable in the setup?
-The jumper cable is used to connect the common terminal of the selector switch to the manual and automatic outputs, ensuring the correct operation of both modes.
What happens if the Radar system fails?
-If the Radar system fails, the pump can still be operated manually through the selector switch, ensuring that the pump remains functional.
Where are the power connections made for the pump?
-The power connections for the pump are made to the terminal block from the contactor, and the neutral connection is made to the T3 terminal or directly to the pump if a socket is not used.
How is the system tested after installation?
-After installation, the system is tested by switching between manual and automatic modes. The pump is checked to ensure it operates correctly in both modes.
Outlines

このセクションは有料ユーザー限定です。 アクセスするには、アップグレードをお願いします。
今すぐアップグレードMindmap

このセクションは有料ユーザー限定です。 アクセスするには、アップグレードをお願いします。
今すぐアップグレードKeywords

このセクションは有料ユーザー限定です。 アクセスするには、アップグレードをお願いします。
今すぐアップグレードHighlights

このセクションは有料ユーザー限定です。 アクセスするには、アップグレードをお願いします。
今すぐアップグレードTranscripts

このセクションは有料ユーザー限定です。 アクセスするには、アップグレードをお願いします。
今すぐアップグレード関連動画をさらに表示

cara membuat pompa galon otomatis tanpa arduino / pompa galon elektrik

PROYEK ARDUINO PENYIRAM TANAMAN OTOMATIS DENGAN SENSOR KELEMBABAN TANAH SIMULASI TINKERCAD ARDUINO

Sistema de Irrigação Automática com Arduino e Sensor de Umidade do Solo

Sistem Penyiraman Tanaman Otomatis dengan Arduino Uno & Sensor Kelembapan Tanah | Easy Solution !!!

How to assemble a 3-phase motor DOL starter (direct on line) circuit

Sistem penyiraman tanaman otomatis esp8266 (BLYNK)
5.0 / 5 (0 votes)