TLDRThis video script demonstrates the process of testing moisture content in sand using a moisture analyzer. The procedure involves preparing three 25-gram sand samples, setting the analyzer to 110ยฐC, and running a 10-minute test. Throughout the process, the temperature, time, and moisture percentage are monitored. After the test concludes, the final weight of the sample is recorded. This detailed, step-by-step guide ensures accurate moisture content measurement and serves as a valuable instructional resource for laboratory procedures.
Takeaways
- ๐ The testing involves measuring the moisture content of sand using a moisture analyzer.
- ๐ Three specimens, each weighing 25 grams, are prepared for the moisture content testing.
- ๐ Essential equipment includes a moisture analyzer, 25 grams of sand per sample, and a moisture analyzer pen.
- ๐ The moisture analyzer is powered on by pressing the on/off button.
- ๐ Temperature is set to 110ยฐC using the F1 button to increase and the F2 button to decrease the temperature.
- ๐ After the temperature reaches 110ยฐC, the enter button is pressed to confirm.
- ๐ The drying time is set to 10 minutes, adjusted with the F1 and F2 buttons.
- ๐ Before placing the sample in the moisture analyzer, the 'Enter' key is pressed to begin calibration, and the display should show zero.
- ๐ The sample is placed in the moisture analyzer, and the lid is closed to begin the test.
- ๐ After the 10-minute testing period, the final weight of the sand is recorded, and the moisture content is calculated as a percentage.
Q & A
What is the primary tool used in the moisture content testing process described in the script?
-The primary tool used for moisture content testing is the moisture analyzer.
How many samples are used for the moisture content testing?
-Three samples, each weighing 25 grams, are used for the moisture content testing.
What is the required temperature setting for the moisture analyzer during the test?
-The temperature is set to 110ยฐC for the moisture analyzer during the test.
How is the temperature adjusted on the moisture analyzer?
-The temperature is adjusted using the F1 and F2 buttons. F1 is used to increase the temperature, and F2 is used to decrease it.
What is the duration of the heating process in the moisture content testing?
-The heating process lasts for 10 minutes.
How is the calibration of the moisture analyzer done before inserting the samples?
-Before inserting the samples, the moisture analyzer is calibrated by pressing 'Enter', which resets the display to zero.
What happens after the samples are inserted into the moisture analyzer?
-Once the samples are inserted, the lid of the moisture analyzer is closed, and the 'Enter' button is pressed to start the moisture content testing process.
How is the moisture content percentage displayed during the test?
-The moisture content percentage is displayed every minute, showing the progress of the test over time.
What should be done once the test reaches the 10-minute mark?
-After 10 minutes, the 'CF' button is pressed to finalize the test, and the final weight of the sample is recorded.
What is the final weight of the sample after the moisture content test?
-The final weight of the sample is 24.18 grams after the moisture content test.
Outlines

This section is available to paid users only. Please upgrade to access this part.
Upgrade NowMindmap

This section is available to paid users only. Please upgrade to access this part.
Upgrade NowKeywords

This section is available to paid users only. Please upgrade to access this part.
Upgrade NowHighlights

This section is available to paid users only. Please upgrade to access this part.
Upgrade NowTranscripts

This section is available to paid users only. Please upgrade to access this part.
Upgrade NowBrowse More Related Video

Uji Kadar Air Serbuk Simplisia dengan Destilasi | Sterling Bidwel | #universitassetiabudi

Lab. Bahan Bangunan - Praktikum Pengujian Berat Jenis dan Kadar Air Kayu

[ANALISIS PANGAN] - MATERI I - Kadar Air Metode Gravimetri

Moisture Content Analysis of Soil

Uji Pemadatan Standar (Standartd Proctor)

Atterberg Test (Liquid and Plastic Limits; Plasticity Index)
5.0 / 5 (0 votes)