How to use an oscilloscope with an A/C source

UCTPhysics
29 Aug 201103:52

Summary

TLDRThe video provides a detailed guide on using an oscilloscope to measure and analyze single-source signals. It explains the setup process, including selecting the correct channel and adjusting trigger settings for optimal signal display. The guide covers key controls for adjusting vertical and horizontal axes, calculating peak-to-peak voltage and signal period, and determining frequency. By counting divisions on the oscilloscope and applying appropriate settings, users can accurately capture and interpret signal characteristics, ensuring a comprehensive understanding of the input signal's behavior.

Takeaways

  • 😀 Ensure the input signal is connected to the correct channel on the oscilloscope.
  • 🔧 Use the trigger controls to display the input signal accurately on the screen.
  • ⚙️ Set the trigger hold-off to auto for optimal signal display.
  • 📏 Adjust the VAR dial to calibrate the gain of the input signal.
  • 📊 The vertical position dial allows you to change the display position of the signal without altering the input.
  • 🔄 The volts per division dial helps scale the displayed voltage for accurate readings.
  • 🔍 To calculate peak-to-peak voltage, count the divisions between the signal's max and min, then multiply by volts per division.
  • 🔄 The horizontal position dial adjusts the signal's display relative to the grid.
  • ⏱️ Use the time per division dial to ensure the entire signal cycle is visible.
  • 🔬 Calculate the signal period by counting horizontal divisions between crests and multiplying by time per division.

Q & A

  • What is the purpose of the trigger controls on an oscilloscope?

    -The trigger controls are used to ensure that the input signal is displayed correctly on the oscilloscope screen.

  • How should the trigger hold-off be set on the oscilloscope?

    -The trigger hold-off should be set to auto by pressing the corresponding button.

  • What does the VAR dial do on the oscilloscope?

    -The VAR dial varies the gain of the input signal and should be set to calibrated mode by turning it clockwise until a click is heard.

  • What is the function of the vertical position dial on an oscilloscope?

    -The vertical position dial changes the position of the signal's display relative to the grid without altering the actual input signal.

  • How do you calculate the peak-to-peak voltage of a signal?

    -To calculate the peak-to-peak voltage, count the number of divisions between the maximum and minimum of the signal and multiply this by the volts per division setting.

  • What might cause discrepancies in peak-to-peak voltage readings?

    -Differences in readings can be due to uncertainty; always choose an appropriate scale that allows measuring both peaks effectively.

  • What does the time per division dial adjust on an oscilloscope?

    -The time per division dial changes the time scale of the displayed signal, ensuring an entire cycle is visible on the screen.

  • How can the period of a signal be calculated?

    -The period is calculated by counting the horizontal divisions between successive crests of the signal and multiplying by the time per division setting.

  • How is frequency related to the period of a signal?

    -Frequency is the inverse of the period; as the period decreases, the frequency increases.

  • Why is it important to ensure the signal spans as much of the screen as possible?

    -It's important for accurate measurement of the peaks and for better visualization of the signal dynamics.

Outlines

plate

此内容仅限付费用户访问。 请升级后访问。

立即升级

Mindmap

plate

此内容仅限付费用户访问。 请升级后访问。

立即升级

Keywords

plate

此内容仅限付费用户访问。 请升级后访问。

立即升级

Highlights

plate

此内容仅限付费用户访问。 请升级后访问。

立即升级

Transcripts

plate

此内容仅限付费用户访问。 请升级后访问。

立即升级
Rate This

5.0 / 5 (0 votes)

相关标签
OscilloscopeSignal MeasurementElectrical EngineeringCalibrationVoltage AnalysisTime AnalysisTechnical SkillsInstrumentationEducationSTEM
您是否需要英文摘要?