Solis Hybrid Inverter - Self-Use Setup

Solis Europe
16 Jun 202202:14

Summary

TLDRIn this instructional video, Travis guides viewers on setting up a Souls Hybrid inverter for self-use, the most common configuration. He emphasizes entering the advanced settings, ensuring the UK G98 standard is selected, and navigating through options such as storage energy, battery selection, and meter placement. Travis advises disabling backup if not in use, setting storage mode to self-use, and allowing grid charging. His concise tutorial ensures viewers can optimize their inverter for efficient home energy use.

Takeaways

  • 🔧 Start by accessing the 'advanced settings' on the inverter to configure the system for self-use.
  • 🔢 Enter the code '00101' to access the specific settings for self-use in the inverter.
  • 🇬🇧 Check the standard setting for 'UK G98' to ensure compatibility with the local grid standards.
  • 🔌 Ensure the 'backup disabled' setting if not using the backup port; otherwise, keep it enabled.
  • 🔋 Select the appropriate battery type, in this case, 'Pylon', for the setup.
  • 📏 Verify the meter type being used, either 'Acryl' or 'Eastron', and ensure it's correctly placed for grid connection.
  • 🔄 Set the 'storage mode select' to 'self-use' to optimize the system for self-consumption of energy.
  • ❌ Make sure the 'charge from grid' setting is on 'allow' to enable charging from the grid when needed.
  • 🛑 Set the 'self-use' mode to 'stop' if you do not want to charge from the grid or use time-of-use settings.
  • 🔄 Turn off other settings like 'backup' and 'off grid' to streamline the system for self-use only.
  • 👋 The script concludes with a reminder to ensure all settings are correctly configured and a sign-off.

Q & A

  • What is the primary purpose of the video?

    -The primary purpose of the video is to guide users on how to set up the Souls Hybrid inverter for self-use, which is the most common setup for the majority of users.

  • What should be the first step when setting up the inverter?

    -The first step is to navigate to the 'Advanced Settings' by going to 'Info Settings', then 'Advanced Info', and finally 'Advanced Settings'.

  • What is the significance of the code 'zero zero one zero' in the setup process?

    -The code 'zero zero one zero' is used to access the advanced settings within the inverter's menu system.

  • What is the standard setting that should be checked in the UK for the inverter?

    -The standard setting to check for in the UK is 'G98'.

  • What is the importance of the 'Storage Energy' setting in the inverter?

    -The 'Storage Energy' setting is crucial as it determines the inverter's operation related to energy storage and usage.

  • Why is it necessary to check the 'Backup Disabled' setting?

    -It is necessary to check the 'Backup Disabled' setting to ensure that the inverter is not set to backup mode unless it is specifically required for use with a backup port.

  • What is the recommended battery selection for the self-use setup?

    -For the self-use setup, it is recommended to select 'Pylon' as the battery type.

  • What meter should be used according to the script?

    -The script suggests using the 'Acryl' meter for one-phase metering, and also mentions the 'Eastron' as an alternative.

  • What should the 'Meter Placement' be set to for grid-connected systems?

    -The 'Meter Placement' should be set to '99 on grid' for grid-connected systems.

  • What is the recommended 'Storage Mode Select' for self-use?

    -For self-use, the 'Storage Mode Select' should be set to 'Self-Use'.

  • What does the 'Self-Use' setting control in the inverter?

    -The 'Self-Use' setting controls whether the inverter prioritizes using stored energy before drawing from the grid and can also be configured for time-of-use scenarios.

  • Why is it recommended to set the 'Charging from Grid' to 'Allow'?

    -Setting 'Charging from Grid' to 'Allow' ensures that the inverter can charge from the grid when necessary, which is almost always the case for 99.99% of users.

  • What other settings should be turned off according to the script?

    -According to the script, other settings that should be turned off include 'Backup' and 'Off Grid'.

Outlines

00:00

🛠️ Setting Up the Soul Hybrid Inverter for Self-Use

Travis introduces a tutorial on configuring the Soul Hybrid inverter for self-use, which he suggests is the most common setup for users. He begins by guiding viewers to access the 'Advanced Settings' of the inverter and emphasizes checking the standard for the UK G98. Travis then instructs to navigate to 'Storage Energy' settings, where he advises disabling the backup if not in use and ensuring the correct battery selection, in this case, Pylon. He also discusses the importance of checking the meter type and setting the meter placement to '99 on grid.' Travis proceeds to explain the 'Storage Mode Select' and sets it to 'Self-Use,' ensuring the selection is active and not in the 'Stop' state. He also mentions the importance of allowing charging from the grid, which is typically enabled by default. Travis concludes by ensuring all other settings, such as backup and off-grid mode, are turned off, summarizing the process with a final check.

Mindmap

Keywords

💡Inverter

An inverter is a device that converts direct current (DC) into alternating current (AC), which is used in homes and businesses. In the context of the video, the inverter is a crucial component of a solar power system, allowing the user to utilize the energy produced by solar panels. The script mentions going into the inverter's 'advanced settings' to configure it for self-use, indicating its importance in managing the solar energy system.

💡Self-Use

Self-use in the script refers to the configuration of a solar power system to prioritize using the energy it generates rather than feeding it back to the grid. This is a common setup for many users, as it maximizes the self-sufficiency of the system. The video provides a step-by-step guide on how to set up the inverter for this purpose, emphasizing its relevance to the majority of users.

💡Advanced Settings

Advanced settings are options within a device that allow for more detailed customization beyond the basic functions. In the video, the presenter instructs the audience to navigate to the inverter's 'advanced settings' to make specific adjustments for self-use. This indicates a deeper level of control over the system's operation.

💡Backup Port

A backup port is a feature in some inverters that allows the system to provide power during a grid outage. In the script, the presenter mentions checking if the backup port is enabled or disabled based on the user's needs, showing the importance of this feature for systems that require backup power.

💡Battery Select

Battery select is a setting that specifies which battery is being used in the solar power system. The script mentions selecting 'Pylon' as the battery, which is an example of a specific battery model. This selection is important for the inverter to properly manage and communicate with the battery.

💡Meter

In the context of solar power systems, a meter is a device that measures the amount of electricity produced and consumed. The script refers to checking the meter type, such as 'Acryl' or 'Eastron,' which are specific brands of meters. Correct meter selection is essential for accurate energy monitoring.

💡Meter Placement

Meter placement refers to the physical location and configuration of the meter within the energy system. The script specifies that the meter placement should be set to '99 on grid,' which is a setting that aligns with the system's connection to the main power grid. Proper placement ensures accurate energy measurement and billing.

💡Storage Mode

Storage mode is a setting that determines how the inverter manages the energy stored in the battery. In the video, the presenter navigates to 'storage mode select' and chooses 'self-use,' which means the system is configured to use the stored energy before drawing from the grid. This mode is central to the self-use setup.

💡Charging from Grid

Charging from the grid refers to the process of the battery drawing power from the main power grid to recharge. The script mentions setting this option to 'allow,' which ensures that the battery can charge when the solar panels do not produce enough energy. This is a key setting for systems that rely on grid power as a backup.

💡Time of Use

Time of use is a billing strategy used by some utilities where the cost of electricity varies depending on the time of day. Although not explicitly detailed in the script, the mention of 'time of use' suggests an alternative to self-use, where charging and usage might be scheduled during off-peak hours to save on costs.

💡Off Grid

Off grid refers to an energy system that is not connected to the main power grid and operates independently. In the script, the presenter advises turning off the 'off grid' setting, which aligns with the self-use configuration that relies on grid connection. This setting is important for systems that may have the capability to operate in both grid-tied and off-grid modes.

Highlights

Introduction to setting up the Souls Hybrid for self-use, which is the most common setup for users.

Accessing the inverter's advanced settings for configuration.

Navigating to the specific menu structure for Souls Hybrid settings.

Entering the advanced settings by inputting 'zero zero one zero'.

Checking the standard for the UK G98 to ensure compatibility.

Accessing the storage energy settings, which are crucial for the setup.

Disabling the backup feature if not using the backup port.

Saving and sending the settings after making adjustments.

Selecting the Pylon battery for the setup.

Verifying the meter type, such as ACR or Eastron, for accurate readings.

Setting the meter placement to '99 on grid' for proper configuration.

Selecting 'self-use' mode in the storage mode settings.

Ensuring the self-use mode is activated and not in the dark color selection.

Configuring the system to stop charging from the grid if not desired.

Allowing the system to charge from the grid by setting it to 'allow'.

Ensuring all other settings such as backup and off-grid are turned off.

Final confirmation of settings and conclusion of the setup tutorial.

Transcripts

play00:00

hey everybody this is travis we're gonna

play00:02

go through the souls hybrid on how to

play00:04

set it up for self-use now self-use is

play00:06

pretty much what 99 of people going to

play00:08

use so this will be your default go-to

play00:10

setup so when you go into the inverter

play00:14

you want to first of all go down to

play00:16

advanced settings so all of our um menu

play00:19

structures all the same info settings

play00:21

advanced info and advanced settings

play00:24

press enter now we want to go zero zero

play00:26

one zero so if you down down up

play00:29

enter

play00:30

now we're in advanced settings

play00:32

so right off

play00:33

you always want to check your standard

play00:35

for

play00:36

the uk g98

play00:38

and then we want to go down to storage

play00:39

energy set that's your bread and butter

play00:41

right there

play00:42

so um you're gonna go first of all i

play00:45

like to go to control panels and make

play00:46

sure the backup disabled it's not if

play00:48

it's enabled uh if you're using it the

play00:51

backup port uh have it enabled if not

play00:53

just disable it

play00:55

save and

play00:56

send and then we're going to go to

play00:59

battery select

play01:01

for this situation we're going to use

play01:02

pylon

play01:04

so that's good that's correct always

play01:06

check your meter

play01:08

so the one phase meter is the acryl

play01:10

meter acr and there's also the eastron

play01:13

so this is correct

play01:16

meter placement is 99 on grid so leave

play01:19

that as is

play01:21

storage mode select is uh where we're

play01:23

gonna go next

play01:24

and we're going to go up to self-use

play01:27

right so self-use

play01:29

now we want to make sure it's on the

play01:30

light colored is the selector not the

play01:32

dark color

play01:33

we have it on and this is the second

play01:35

stage of selfies do you want to charge

play01:37

from grid and or do you want to do time

play01:39

of use right now we want to just do self

play01:41

use so we go in here we make sure it

play01:43

says stop that's correct

play01:45

save and send

play01:47

and then for charging from grid almost

play01:49

99.99 you're gonna have it on allow if

play01:52

you have it on not allow it won't force

play01:54

charge so always make sure it's on allow

play01:58

you come out of there and then

play02:00

uh what i like to do is i like to make

play02:02

sure everything else is off

play02:03

[Music]

play02:05

so my backup is off

play02:07

and off grid is off and that's it thanks

play02:09

guys bye

play02:11

[Music]