MLAstro SHG Focusing Procedure
Summary
TLDRThis instructional video explains how to calibrate and focus a spectrograph, specifically focusing on adjusting the camera and grating. It covers the procedure for achieving accurate infinity focus using a faraway object, then proceeds with the detailed steps for focusing the camera, adjusting the exposure, and fine-tuning the focus with a micrometer. The video also walks through mounting the SHG, adjusting the micrometer, and achieving clear, sharp focus on the slit and spectrum. Although the spectrograph comes pre-calibrated, this process is useful for those needing to perform calibration themselves.
Takeaways
- 😀 Pre-calibrated spectrometer can be adjusted if needed, including refocusing the lens or collimator.
- 😀 To calibrate, focus the camera lens on a far object at infinity for proper focus.
- 😀 The camera lens assembly can be adjusted by removing the collimator lens and refocusing the grating.
- 😀 The grating acts as a mirror to reflect incoming beams, aiding in proper calibration.
- 😀 Ensure that the camera is installed with the long edge facing the micrometer for proper orientation.
- 😀 To adjust the camera focus, use the micrometer to achieve an even and smooth focus.
- 😀 A distant object (at least 2 km away) is ideal to ensure the camera focuses at infinity.
- 😀 Fine adjustments can be made using the micrometer for both camera and slit focus.
- 😀 After focusing the camera at infinity, reattach the collimator lens and micrometer.
- 😀 When adjusting the slit focus, ensure the slit is clean and the spectral line is sharp for optimal calibration.
- 😀 The calibration process is optional if the spectrometer was pre-calibrated, but it is essential to follow these steps if re-calibration is needed.
Q & A
What is the first step in the calibration process for the spectrograph?
-The first step is to focus the lens with the camera at infinity, which involves adjusting the camera's focus on a far-away object.
How can the lens assembly be refocused if it's not removable?
-If the lens assembly cannot be removed, refocus is done by removing the collimator lens and adjusting the focus using the camera lens and a grating.
What is the role of the grating in the calibration process?
-The grating acts as a mirror during calibration, reflecting the incoming beam from the camera to help with alignment.
Why is the camera oriented a certain way when installing it on the spectrograph?
-The camera should be oriented with its long edge pointing towards the micrometer to ensure proper alignment, although perfect precision is not required initially.
What is the significance of choosing a far-away object for focusing the camera?
-Choosing a far-away object, such as a building 2 km away, ensures that the camera focuses at infinity, preventing issues with near-focus adjustments and calibration errors.
What should be done if the focus on the camera is not fine enough?
-If the focus is not fine enough, adjustments can be made using the micrometer to fine-tune the focus until it's as sharp as possible.
What happens after the camera focus is adjusted?
-After the camera focus is adjusted, the collimator lens and micrometer are put back, and the slit is checked for focus.
How do you adjust the focus of the slit?
-The slit focus is adjusted by using the micrometer to make fine adjustments to ensure a sharp and clear image of the slit.
What is the purpose of locking the grating in place during calibration?
-Locking the grating ensures that it remains stationary while the micrometer is used to make precise micro-adjustments during the calibration process.
Is it necessary to recalibrate the spectrograph out of the box?
-No, the spectrograph is pre-calibrated before shipping. However, if recalibration is needed in the future, the provided steps should be followed.
Outlines

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantMindmap

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantKeywords

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantHighlights

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantTranscripts

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantVoir Plus de Vidéos Connexes

Autodesk Inventor #6 Cara Melakukan Explode View

Cara Mengalibrasi (Kalibrasi) Osiloskop Analog - 2122600059

Belajar Cara Menggunakan Oscilloscope Digital | Cara Kalibrasi Oscilloscope Digital

3D Rendering in AutoCAD

MERAWAT SECARA BERKALA MEKANISME KATUP

CAMERA BASIC 2 | Belajar DASAR KAMERA Untuk Pemula.. !!
5.0 / 5 (0 votes)