Bone Density Screening using Achilles - How To Set Up Machine

Lawrence Davidow
23 Aug 201910:56

Summary

TLDRThis informal video provides a step-by-step guide on setting up and maintaining a bone density machine. It emphasizes the importance of using distilled water, properly replacing diaphragms, and conducting quality assurance checks. Viewers learn how to drain and refill the machine, as well as replace thermal paper for patient reports. Key tips include ensuring the machine is kept at a stable temperature and avoiding frequent powering off. The detailed instructions aim to ensure effective use and longevity of the machine.

Takeaways

  • 🔌 Ensure the bone density machine is properly set up with the power cord connected; an extension cord may be necessary.
  • 💧 Always use distilled water to fill the machine's diaphragms; tap water can cause mineral buildup.
  • 🧼 Regularly check the machine for water levels; replace water if a QA failure occurs.
  • 🔧 Familiarize yourself with the mechanical components of the machine, including the diaphragm and water screw.
  • 🛠️ Replace the membranes if they leak; keep spare membranes on hand during training.
  • 📜 Be aware of the importance of replacing the thermal paper for patient report prints.
  • 🕒 Allow the machine to warm up for 10-15 minutes before running tests after it’s turned on.
  • ⚠️ Do not leave the machine in extreme temperatures, as water inside can freeze and damage the equipment.
  • 👀 Conduct a quality assurance check after the machine is turned on to ensure proper functioning.
  • 🔄 Once QA is performed, avoid turning off or moving the machine to prevent the need for another QA.

Q & A

  • What is the first step in setting up the bone density machine?

    -The first step is to carefully take the machine out of its hard shell and ensure that it is connected to a power source, considering the length of the power cord.

  • Why is it important to use distilled water in the bone density machine?

    -Distilled water is essential because tap water can contain calcium or mineral deposits that may damage the machine.

  • What should you do if the machine indicates a QA failure related to the water?

    -You need to drain the old water and refill the machine with distilled water, as contaminants can affect its performance.

  • How do you drain the water from the machine?

    -To drain the water, unscrew the big black screw, tilt the machine carefully, and let the water drain out.

  • What maintenance is required for the rubber diaphragms?

    -The rubber diaphragms need to be inspected regularly and replaced if they develop leaks.

  • How can you tell if the rubber diaphragm is installed correctly?

    -The flat side of the diaphragm should face outward, and it should fit snugly into the grooves of the machine.

  • What happens if the machine is left in a cold environment?

    -If the machine is left in a cold environment, the water inside could freeze, potentially damaging the equipment.

  • What is the purpose of the thermal paper in the machine?

    -The thermal paper is used for printing patient reports, and it may need to be replaced periodically.

  • What should you do before running a test with the bone density machine?

    -You need to perform a quality assurance (QA) check after turning on the machine and before running any tests.

  • What is the significance of the 'Phantom' in the setup process?

    -The Phantom is a test object used to ensure the machine is calibrated correctly before actual patient testing.

Outlines

plate

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.

Mejorar ahora

Mindmap

plate

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.

Mejorar ahora

Keywords

plate

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.

Mejorar ahora

Highlights

plate

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.

Mejorar ahora

Transcripts

plate

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.

Mejorar ahora
Rate This

5.0 / 5 (0 votes)

Etiquetas Relacionadas
Bone DensityMachine SetupHealthcare TrainingUltrasound DeviceQuality AssuranceMedical EquipmentMaintenance TipsTraining VideoDistilled WaterPatient Reports
¿Necesitas un resumen en inglés?