How to determine split tensile strength test of concrete || Laboratory Concrete Test #2
Summary
TLDRThe video explains the procedure for conducting split tensile strength tests on concrete cylinders. The test measures tensile strength by applying a compressive force along the cylinder's length using a universal testing machine. The concrete specimen is prepared, cured, and tested at different intervals (7, 14, and 28 days). Load is applied continuously until the cylinder fails, and the split tensile strength is calculated using a specific formula. The video also highlights the setup process, including aligning bearing strips and noting the load at which failure occurs.
Takeaways
- 🔍 The split tensile strength test measures the tensile strength of concrete using a compressive force along the length of a concrete cylinder.
- 🧱 The test specimen is a cylindrical concrete sample with dimensions of 150 mm in diameter and 300 mm in length.
- 🛠️ A universal testing machine is used to perform the split tensile strength test.
- 📏 The concrete specimen is prepared in layers, with each layer tamped 25 times to ensure compaction.
- 💦 After a day, the mold is removed and the specimen is placed in a curing tank at 27 ± 2°C for a specified period.
- ⏲️ Specimens are tested after curing for 7, 14, or 28 days depending on the requirements.
- ✍️ The weight and dimensions of the specimen are recorded before testing, and markings are drawn on the surface for alignment.
- 📐 The specimen is placed in the testing machine with plywood bearing strips on both sides, and optionally supplement bars depending on the diameter.
- 📈 Load is applied continuously at a rate between 1.2 to 2.4 MPa per minute until the cylinder fails, creating cracks.
- 📝 The split tensile strength is calculated using the formula: 2P / (π * D * L), where P is the load at failure.
Q & A
What is the purpose of the split tensile strength test on concrete?
-The split tensile strength test is used to determine the tensile strength of concrete by applying a compressive force along the length of a cylindrical concrete specimen.
What are the dimensions of the cylindrical specimen used in this test?
-The cylindrical specimen has a diameter of 150 millimeters and a length of 300 millimeters.
Which equipment is used for conducting the split tensile strength test?
-The Universal Testing Machine (UTM) is used to conduct the split tensile strength test.
How is the concrete specimen prepared for the split tensile strength test?
-The specimen is prepared by placing the concrete mixture in layers inside a mold and tamping each layer with 25 blows. After 24 hours, the mold is removed, and the specimen is placed in a curing tank at 27 ± 2°C.
At what intervals are the specimens tested after being placed in the curing tank?
-The specimens are tested at intervals of 7, 14, and 28 days after being removed from the curing tank.
How is the specimen placed in the Universal Testing Machine for the test?
-The specimen is placed longitudinally in the machine, with bearing strips made of plywood placed on both sides. It is then aligned according to the marked lines on the specimen.
What is the loading rate applied during the split tensile strength test?
-The load is applied continuously at a rate within the range of 1.2 to 2.4 MPa per minute.
How is the split tensile strength of the concrete calculated after the test?
-The split tensile strength is calculated using the equation 2P / (π × D × L), where P is the load at which the specimen fails, D is the diameter, and L is the length of the specimen.
Why are supplement bars sometimes used during the test?
-Supplement bars are sometimes placed on top of the plywood bearing strips depending on the diameter of the specimen to ensure even distribution of the applied load.
What factors could affect the results of the split tensile strength test?
-Factors that can affect the test results include improper specimen preparation, incorrect curing temperatures, variations in the load application rate, and misalignment of the specimen in the testing machine.
Outlines
🧪 Introduction to Split Tensile Strength Test
This section introduces the split tensile strength test for concrete. It explains that the tensile strength is determined by applying a compressive force along the length of a cylindrical concrete specimen. The cylinder used has a diameter of 150 mm and a length of 300 mm, and the test is performed using a universal testing machine.
🔧 Preparation of the Test Specimen
Here, the procedure for preparing the concrete specimen is described. The specimen is molded in layers and each layer is tamped with 25 blows. After one day, the mold is removed and the specimen is placed in a curing tank at a controlled temperature of 27 ± 2°C. The specimen is kept in the tank for 7, 14, or 28 days, depending on the test requirement.
📝 Marking and Weighing the Specimen
This part focuses on the preparation for the actual test. The line marking on the specimen, as shown in the video, is explained. The weight and dimensions of the specimen are recorded before proceeding with the test. The specimen is positioned longitudinally in the testing machine with plywood bearing strips placed on both sides for alignment.
⚖️ Applying Load and Measuring Strength
The test process begins with applying a continuous load to the specimen at a rate of 1.2 to 2.4 MPa per minute. The load is applied until the cylinder develops cracks and fails. The split tensile strength is calculated using the equation 2P/πDL, where P is the load at failure.
🎬 Conclusion and Call to Action
This final segment concludes the video, encouraging viewers to like, share, comment, and subscribe to the channel for more content. It also hints that more informative videos are coming soon.
Mindmap
Keywords
💡Split tensile strength test
💡Concrete cylinder
💡Compressive force
💡Universal testing machine
💡Specimen preparation
💡Curing tank
💡Bearing strip
💡Load application rate
💡Cracks
💡Tensile strength equation
Highlights
The split tensile strength test on concrete measures tensile strength by applying compressive force along the length of a concrete cylinder.
The concrete cylinder used in the test is 150 millimeters in diameter and 300 millimeters in length.
The universal testing machine is used to conduct the split tensile strength test.
The concrete specimen is prepared using standard manufacturing procedures and placed in layers, with each layer tamped using 25 blows.
After one day, the mold is removed, and the specimen is placed in a curing tank at a temperature of 27 ± 2 degrees Celsius.
The specimen is tested for tensile strength at intervals of 7, 14, and 28 days after curing.
A line is drawn on the specimen before testing, and its weight and dimensions are recorded.
The specimen is placed longitudinally in the testing machine with a plywood bearing strip on both sides.
In some cases, supplement bars are placed on top of the plywood based on the diameter of the specimen.
The load is applied continuously at a rate between 1.2 to 2.4 MPa per minute.
The test records the load at which the concrete cylinder fails by developing cracks.
The split tensile strength is calculated using the formula: 2P / (πDL), where P is the load at which the specimen breaks.
The split tensile strength test provides critical data for understanding the tensile behavior of concrete under compressive forces.
Curing temperature control and timing (7, 14, and 28 days) significantly influence the concrete's tensile strength.
This method is commonly used to evaluate concrete’s durability and performance in various structural applications.
Transcripts
[Music]
split tensile strength tests on concrete
in the split tensile strength test the
tensile strength of concrete is obtained
by applying a compressive force along
the length of the concrete cylinder
the specimen used for this method is of
cylindrical in size and dimensions of
150 millimeters in diameter and 300
millimeters in length
the instrument used for this method is
the universal testing machine
the specimen is prepared in the standard
manufacturing procedure and placed on
the mold in layers and tamped using 25
blows for each layer
after a day the mold is removed and the
specimen is placed in the curing tank at
a temperature of 27 plus or minus 2
degrees Celsius
depending upon the requirement the test
specimen is removed from tank and dried
at 7:14 and 28 days for testing
draw the line on the specimens as
displayed on the screen
then record the weight and dimension of
the specimen
the specimen is placed longitudinally in
the machine
a bearing strip made up of plywood is
placed on both sides of the specimen and
align it according to the marking
sometimes supplement bars are placed on
top of the plywood depending upon the
diameter of the specimen
now apply the load continuously at a
rate within the range 1.2 to 2.4 MPA per
minute
finally note down the load at which
cylinder fails by developing cracks
the resultant split tensile strength is
calculated by the equation 2 P divided
by fee into D into L
where P is equal to load at which the
specimen breaks
thank you for watching stay tuned the
best is yet to come
kindly do like share comment your views
and finally don't forget to subscribe
our Channel
Weitere ähnliche Videos ansehen