Seismic and Wind 1 of 3
Summary
TLDRThe script discusses a building's structural analysis in San Guillermo Isabella, referencing the NCSP 2015 for seismic and wind load calculations. It covers determining the nearest fault line, seismic source type, and near-source factors for earthquake resistance. For wind load, it details calculating risk category, basic wind speed, and topographic factors for a low-rise building. The process includes interpolating wind pressures for different zones and truss dimensions, ultimately computing design wind pressures and loads for structural components.
Takeaways
- đą The building is located in San Guillermo Isabella and is being assessed according to the NSCP 2015 guidelines.
- đ The nearest fault line is measured to be 12 kilometers away from the building using a specific scale.
- đ The seismic source type is classified as Type A, and the magnitude range is between 7 to 8.4.
- đ The Near Source Factor 'Na' is determined to be 1, as the distance is greater than 10 kilometers.
- đïž For wind load assessment, the building is categorized as a low-rise structure less than 18 meters in height.
- đ The risk category is determined as 'C' and the basic wind speed 'V' is identified as 290 kph from a map.
- đ Topographic and importance factors are assumed to be 1 for general flat terrain and standard occupancy category 4.
- đ The mean roof height 'h' is 10.7 meters, which is used to determine the wind load parameters.
- đȘïž The net design wind pressure is calculated by interpolating values between wind speeds of 250 and 300 kph.
- đą The effective area for truss andææ(possibly a typo or misheard word, consider checking the transcript) is calculated using specific formulas.
- âïž The wind forces for different zones are computed, taking into account the truss spacing and adjustment factors.
Q & A
What is the building location mentioned in the transcript?
-The building is located in San Guillermo, Isabella.
What is the purpose of Figure 208-2D from NSCP 2015?
-Figure 208-2D from NSCP 2015 is used to determine the Near Source Factor and the Seismic Source Type based on the building's location and the distance to the nearest fault line.
How is the Near Source Factor (N) determined in the transcript?
-The Near Source Factor (N) is determined based on the distance from the building to the nearest fault line, which is measured to be 12 kilometers, indicating a value of N as 1 since the distance is greater than 10 kilometers.
What seismic source type is identified for the building?
-The seismic source type identified for the building is Type A, based on the information provided in the transcript.
What is the process for determining the wind load parameters in the transcript?
-The process involves determining the risk category, basic wind speed, topographic factor, importance factor, mean roof height, and then using these parameters to calculate the net design wind pressure.
What is the basic wind speed (V) for the building location according to the transcript?
-The basic wind speed (V) for the building location is 290 kph, as determined from the map in Figure 207-A.5-1.
What is the topographic factor (Kjt) assumed for the building?
-The topographic factor (Kjt) is assumed to be equal to 1, which is for generally flat terrain.
How is the mean roof height (h) used in the calculation of wind load parameters?
-The mean roof height (h) is used to determine the wind load parameters by interpolating between the values provided in Figure 207-8.5-1 based on the roof height and exposure category.
What is the effective wind area for the truss and the Berlin in the transcript?
-The effective wind area for the truss is the minimum of 2.25 * 13.1 square meters or 9.5 square meters, while for the Berlin, it is calculated as the maximum of (2.25 / 3) * 2.25 * 0.8 square meters or 1.8 square meters.
How are the net design wind pressures (Pn) calculated for different zones in the transcript?
-The net design wind pressures (Pn) are calculated by interpolating between the wind pressures for areas of 1 square meter and 2 square meters at different wind speeds (250 and 300 kph), and then adjusting for the specific wind speed of 290 kph.
What is the final step in calculating the wind forces for the building components?
-The final step is to compute the loads for the components by multiplying the adjustment factor, the topographic factor, the net design wind pressure, and the component spacing.
Outlines
Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantMindmap
Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantKeywords
Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantHighlights
Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantTranscripts
Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.
Améliorer maintenantVoir Plus de Vidéos Connexes
Calculate Wall Bracing - Part 2- Determine Wind Pressure
Piperack Loading | Different pipe Loads on Piperack | Piping Mantra |
Design of Steel Warehouse in ETABS | Portal Frame, Wall and Roof Bracing, Fly Braces, Wind load |
Tips Mudah Menentukan Ukuran Pondasi Cakar Ayam Rumah 2 Lantai
Pendahuluan hukum dan konsep dasar
Calculate Wall Bracing - Part 3 - Calculate the Area of Elevation and Calculate the Racking Force.
5.0 / 5 (0 votes)