Acid Waste pH Neutralization (AWN) Theory and Operations
Summary
TLDRThe pH neutralization system is an automated process designed to control the pH of wastewater before discharge. It uses chemicals like sodium hydroxide and sulfuric acid to neutralize acidic or basic solutions, ensuring they fall within an acceptable pH range. The system includes a control panel, chemical metering pumps, and pH electrodes for precise monitoring and adjustment. The wastewater is mixed and treated in stages, with adjustments made based on pH readings. Once neutralized, the treated water is discharged under gravity flow, with final pH levels and flow rates continuously recorded for monitoring purposes.
Takeaways
- 😀 pH is a measure of acidity or alkalinity in water, ranging from 0 to 14, where values less than 7 indicate acid and values greater than 7 indicate a base.
- 😀 pH neutralization systems are used to adjust wastewater pH to a defined, acceptable range before discharge into the environment.
- 😀 Acidic solutions are neutralized by bases (like sodium hydroxide), while basic solutions are neutralized by acids (like sulfuric acid).
- 😀 The neutralization process creates salts and water as byproducts, which may or may not be sellable.
- 😀 Common chemicals used for neutralization include 98% sulfuric acid and 50% sodium hydroxide, but their selection should consider factors like health and safety, cost, and ease of operation.
- 😀 The pH neutralization system has automatic controls and alarm systems to ensure the correct pH balance is achieved.
- 😀 The pH neutralization process involves multiple stages where chemicals are added to either raise or lower the pH of the solution as needed.
- 😀 The system uses a pH electrode to measure and display the pH of the water on a control panel, guiding the chemical dispensing process.
- 😀 If the pH rises above a set threshold (e.g., 9.0), acid is added to bring it back to the desired range (e.g., 7.5).
- 😀 The final pH is monitored through a final pH meter, and the discharge flow rate is recorded on a digital chart recorder for tracking and documentation.
- 😀 After treatment, the neutralized wastewater flows by gravity to the sewer, completing the discharge process.
Q & A
What is the primary function of the pH neutralization system?
-The primary function of the pH neutralization system is to control the pH of wastewater before it is discharged, ensuring it meets the defined acceptable discharge range.
How is pH measured and what does it indicate?
-pH is measured on a scale from 0 to 14. Solutions with a pH of less than 7 are acidic, while those with a pH greater than 7 are alkaline (or basic). pH indicates the acidity or alkalinity of a solution.
What chemicals are commonly used in pH neutralization processes?
-The most commonly used chemicals for pH neutralization are 98% sulfuric acid (for neutralizing bases) and 50% sodium hydroxide (NaOH, for neutralizing acids).
Why is the selection of chemicals important in the neutralization process?
-The selection of chemicals is crucial for ensuring safety, cost-effectiveness, operational convenience, and environmental compatibility. Factors such as health and safety, cost, storage conditions, and ease of handling must all be considered.
What are the basic chemical principles behind pH neutralization?
-To neutralize an acid, a base (excess hydroxide ions, O-) is added, while to neutralize a base, an acid (excess hydrogen ions, H+) is required. This process results in the formation of salts and water.
What happens when the pH value exceeds 9.0 in the system?
-If the pH value exceeds 9.0, the acid pump dispenses acid to reduce the pH back to a target value of 7.5, ensuring the solution stays within the acceptable pH range.
How is pH monitored in the neutralization system?
-pH is monitored using a pH electrode that senses the pH level in the solution. The data is displayed on a control panel for continuous monitoring.
What is the role of the chemical metering pumps in the system?
-Chemical metering pumps are responsible for dispensing the chemicals, such as sodium hydroxide (for increasing pH) or acid (for decreasing pH), into the wastewater to adjust its pH to the desired level.
How does the solution flow through the stages of pH neutralization?
-The wastewater first enters the primary pH neutralization tank, where chemicals are added to adjust the pH. After mixing, the solution flows to the second tank for further pH adjustment, and then gravity feeds to the final monitoring device for discharge.
What is the purpose of the final pH monitoring device in the system?
-The final pH monitoring device is used for monitoring the pH of the treated wastewater. It records the pH value and flow rate, but does not control chemical dispensing.
What happens after the wastewater has been treated and pH levels are stabilized?
-After the pH has been adjusted and stabilized, the treated wastewater flows through a final pipeline, under gravity, to the sewer for discharge.
Outlines
此内容仅限付费用户访问。 请升级后访问。
立即升级Mindmap
此内容仅限付费用户访问。 请升级后访问。
立即升级Keywords
此内容仅限付费用户访问。 请升级后访问。
立即升级Highlights
此内容仅限付费用户访问。 请升级后访问。
立即升级Transcripts
此内容仅限付费用户访问。 请升级后访问。
立即升级浏览更多相关视频
GCSE Chemistry - Acids and Bases #34
GCSE Chemistry: Understanding pH Titration Curves for Neutralisation Reactions
Berapakah harga pH larutan campuran 100 mL larutan 0,6 M CH_(3) COOH dengan 100 mL larutan ...
pH Meter Calibration
Sistem Informasi Online Monitoring Kualitas Air Sungai di Kabupaten Probolinggo
Salt Hydrolysis | Buffer : Definition & Action | SK015 Chapter 7.1 Part III
5.0 / 5 (0 votes)