Budget-Friendly, Versatile, Full-Featured: DABBSSON DBS3500 240V Split-Phase Solution

ReeWray Outdoors
2 Jun 202411:32

Summary

TLDR本视频是对Dobson DBS 3500便携式家用备用电源系统的深入介绍。演示了如何通过连接两个DBS 3500设备实现240伏特的分相输出,用于驱动大型家用电器。视频详细展示了如何使用并联盒和L450连接器进行设备连接,并强调了平衡负载以避免系统过载的重要性。同时,提醒观众在分相模式下不能通过交流电充电,需通过直流电如太阳能充电。视频还测试了系统在实际使用中的表现,包括运行热水器和污水泵等。

Takeaways

  • 🔌 Dobson DBS 3500是一款性价比高的便携式家用备用电源系统。
  • 🚀 通过使用扩展电池,DBS 3500可以变成一个多功能的便携式电源站。
  • 🔗 连接两个DBS 3500可以创建一个240伏的分裂相输出。
  • 🔌 需要一个并联盒来连接两个DBS 3500,它带有L450和L1430扭锁连接器。
  • 🔄 每个DBS 3500可以单独输出240伏或20安培120伏的电。
  • 🔋 两个DBS 3500并联后,可以提供最多7200瓦的240伏服务。
  • 🏠 这种配置适合为家中的大型电器供电,如烘干机或电热水器。
  • ⚠️ 并联使用时,需要注意负载平衡,以避免一个单元比另一个更快耗尽电量。
  • 🔌 在分裂相模式下提供交流电时,不能通过交流电充电,只能通过直流电充电。
  • 👍 视频作者对DBS 3500的性能感到满意,并推荐了这款预算友好的家用备用电源系统。

Q & A

  • Dobson DBS 3500是什么设备?

    -Dobson DBS 3500是一种便携式家用备用电源系统或便携式电源站,具有轮子和手柄,便于携带。

  • 如何使用Dobson DBS 3500进行电池扩展?

    -通过连接扩展电池,Dobson DBS 3500可以变成一个多功能的便携式家用备用电源系统。

  • Dobson DBS 3500的成本效益如何?

    -在成本每瓦时的计算上,Dobson DBS 3500是市场上较好的预算选择之一。

  • 如何将两台Dobson DBS 3500连接起来?

    -需要使用随设备附带的并联盒,该盒子上有L450连接器和L1430旋转锁,通过这些连接器将两台设备连接起来。

  • 并联两台Dobson DBS 3500后可以得到什么样的输出?

    -并联后可以得到240伏的分裂相输出,每个端口可以输出20安培的120伏或30安培的240伏。

  • 为什么需要平衡两个120伏的负载?

    -为了确保两个独立的AC逆变器供电的两个相位之间的负载相对平衡,避免一个单元比另一个更快耗尽电量,导致整个系统关闭。

  • Dobson DBS 3500是否适合为大型家用电器供电?

    -是的,它适合为大型家用电器供电,如烘干机或大型电热水器,但不推荐用于启动典型的家用中央空调系统。

  • 如果需要为Dobson DBS 3500充电,应该怎么做?

    -在分裂相模式下提供交流电时,不能通过交流电充电,只能通过直流电充电,例如太阳能或其他直流输入。

  • Dobson DBS 3500的容量是多少?

    -单台Dobson DBS 3500的容量大约是3420瓦时,两台并联后大约有7000瓦时的容量。

  • Dobson DBS 3500是否适合作为家庭备用电源系统?

    -是的,Dobson DBS 3500非常适合作为家庭备用电源系统,性价比高,且在实际使用中表现出色。

Outlines

00:00

🔌 并联DBS 3500电源系统

本段介绍了如何使用Dobson DBS 3500电源系统进行并联,以实现240伏特的分相输出。首先需要两个DBS 3500电源,通过并联盒连接,该盒子带有L450和L1430连接器。并联后,每个电源可以提供120伏特20安培或240伏特的输出,但总输出不能超过30安培。并联操作后,系统会自动重新启动以设置分相。此外,还讨论了使用这种电源系统供电大型家用电器的可能性,如烘干机或热水器,但指出它不适用于启动家用中央空调系统的初始电流。

05:00

🔄 平衡负载以维持电源稳定

这段内容强调了在使用分相240伏特电源时,保持两个120伏特电源负载平衡的重要性。如果负载不平衡,一个电源可能会比另一个更快耗尽,导致整个系统关闭。介绍了如何通过添加扩展电池来增加电源容量,建议为每个DBS 3500添加两个扩展电池以保持容量一致。此外,还提到了测试电源输出是否达到240伏特,并展示了如何通过手动转换开关连接电源系统。还讨论了在分相模式下不能通过交流电充电的限制,以及如何通过直流电(如太阳能)充电。

10:01

🌟 Dobson DBS 3500电源系统评价

在这段视频中,作者分享了他对Dobson DBS 3500电源系统的评价,认为它是一个性价比高的家庭备用电源系统。作者提到,尽管价格不高,但该系统在他使用四个多月的时间里表现出色,满足了他的需求。视频最后,作者鼓励观众如果觉得视频有用或有趣,可以点赞支持,并感谢观众的观看。

Mindmap

Keywords

💡Dobson DBS 3500

Dobson DBS 3500是一种便携式家用备用电源系统或便携式电源站。在视频中,它被用来展示如何通过扩展电池来构建一个经济实惠的便携式电源解决方案。DBS 3500因其性价比高和实用性而受到推荐。

💡扩展电池

扩展电池是用于增加DBS 3500电源系统容量的组件。在视频中提到,通过使用扩展电池,DBS 3500可以变成一个多功能的便携式电源解决方案,增强了其作为家用备用电源系统的实用性。

💡并联盒

并联盒是一种用于连接两个DBS 3500以实现240伏特分相输出的设备。视频中提到了并联盒的具体型号和连接器类型,如L450和L1430,展示了如何使用并联盒来连接两个电源系统。

💡分相240伏特输出

分相240伏特输出是指通过将两个DBS 3500并联,从而获得的更高电压输出。这种配置允许电源系统为需要更高电压的大功率电器供电,如干衣机或电热水器。

💡负载平衡

负载平衡是指在电源系统中均匀分配电力负载,以避免一个电源单元比另一个更快耗尽。视频中强调了在使用分相240伏特配置时,保持两个120伏特电源腿负载平衡的重要性。

💡手动转换开关

手动转换开关是一种允许用户在不同电源之间切换的设备。在视频中,它被用来展示如何将DBS 3500系统连接到家庭电路中,以在停电时提供备用电源。

💡L1430扭锁连接器

L1430扭锁连接器是一种常用于发电机和某些电器的连接器类型。视频中提到了使用L1430连接器的电缆来连接DBS 3500系统和手动转换开关。

💡AC逆变器

AC逆变器是将直流电转换为交流电的设备,使得电源系统能够为家庭电器供电。视频中提到了DBS 3500中的AC逆变器,以及如何通过并联配置来提供240伏特的交流电输出。

💡持续功率输出

持续功率输出是指电源系统能够持续提供的最大功率。视频中提到DBS 3500每个单元能够提供3600瓦的持续AC输出,但需要注意不要超过30安培的最大限制。

💡太阳能充电

太阳能充电是指使用太阳能电池板为电源系统充电的方式。在视频中提到,在分相模式下提供交流电时,DBS 3500不能通过交流电充电,而需要通过直流电,如太阳能充电来补充电量。

Highlights

介绍了Dobson DBS 3500的扩展电池使用,使其成为便携式家用备用电源系统。

展示了如何连接两个DBS 3500以实现240伏特的分裂相输出。

需要两个DBS 3500和一个并联盒来实现分裂相配置。

并联盒带有L450和L1430连接器,可以输出240伏特或120伏特20安培。

通过两个电缆将两个DBS 3500连接到并联盒,实现并联。

设备启动后会自动检测并联盒并设置分裂相。

每个DBS 3500能提供3600瓦特的连续AC输出。

并联使用时,不能处理典型住宅中央空调的启动电流。

适合用于窗式或地面空调等大型电器。

使用标准发电机电缆或L450到L1430的适配器连接手动转换开关。

设置手动转换开关时,需要平衡两个120伏特电源的负载。

如果负载不平衡,一个单元会比另一个更快耗尽电量。

可以添加扩展电池,但需要为每个单元添加相同数量的电池。

两个DBS 3500的组合可以提供高达7200瓦特的240伏特服务。

使用万用表测试输出,确认得到了240伏特。

演示了如何将负载切换到DBS 3500系统。

强调了平衡负载的重要性,以避免一个单元先耗尽电量。

DBS 3500系统足以在冬季为燃气或丙烷炉提供动力。

在分裂相模式下提供AC电源时,不能通过AC充电,只能通过DC充电。

对DBS 3500的性能表示满意,并推荐了该产品。

Transcripts

play00:00

hey thanks for joining me this is just a

play00:01

quick video kind of a followup to the

play00:03

video that I did on this uh Dobson DBS

play00:06

3500 about a month or maybe five or six

play00:10

weeks ago but then I showed you uh how

play00:12

you could use this with an expansion

play00:14

battery and it makes a very nice

play00:17

versatile budget portable home backup

play00:20

system or portable power station either

play00:22

way you can kind of take it with you

play00:24

it's got a dolly handle and wheels and

play00:26

uh it's got battery expansions and and

play00:30

terms of cost per wat hour it's one of

play00:32

the the better budget options out there

play00:35

that I have seen well in today's video

play00:37

we're going to take a look at how you

play00:38

can connect two of these DBS 3500s

play00:40

together to get a split phase 240 volt

play00:43

output and to do that you obviously have

play00:46

to have two of the DBS 3500s and by the

play00:49

way if you haven't seen the the

play00:50

individual video that I did on it uh

play00:52

I'll put that in the video description

play00:53

below and you can go check that out I

play00:54

highly recommend that this will make a

play00:56

whole lot more sense if you if you do go

play00:58

watch that but uh back back to this

play01:00

topic where we're going to look at this

play01:01

240 volt split phase configuration now

play01:04

you do need this parallel box that that

play01:07

they ship with this and on this it has

play01:09

an l450 connector even though this

play01:12

really is a 30 amp output it's a maximum

play01:14

of 30 amps but it does have an l450 type

play01:18

kind of the same thing you would use for

play01:19

a a dryer also very common for uh for

play01:22

RVs as well and then it's got an l1430

play01:25

twist lock over here and uh and you can

play01:28

actually get 240 vol Vols out of either

play01:30

one of these two or you can get 20 amps

play01:33

120 volts out of either one of these two

play01:36

but again uh maximum 30 amps out of the

play01:39

the whole thing and basically there's

play01:41

just two cables coming off this as you

play01:43

can see on the top and those wrap around

play01:45

and they plug into each of these DBS

play01:48

3500 Infinity ports on the side and they

play01:51

just plug right in there and then all

play01:53

you have to do is power up the units

play01:55

it'll detect that there's this parallel

play01:57

box attached and then you will kind of

play02:00

reboot itself to set the split phase for

play02:02

you and then you're off to the races so

play02:05

let's uh let's go ahead and do

play02:08

that and like I said they'll kind of

play02:10

boot up and then they'll shut off and

play02:12

then they'll boot up

play02:14

again now they're powering

play02:20

down and they are coming back

play02:23

up all right so they're pretty close in

play02:26

charge 98% 99% now typically when you're

play02:29

you're trying to get 240 volt output is

play02:31

because you want to be able to power

play02:33

larger appliances in your house like

play02:34

your dryer or some big monster electric

play02:37

water here like this or your furnace

play02:40

which actually doesn't typically take

play02:41

240 volts but your central AC will but

play02:44

do be aware even though these are rated

play02:46

for a continuous 3600 watts of AC output

play02:51

uh each at 30 amp Max is not going to be

play02:54

enough to allow you to handle the inrush

play02:57

current on a typical sort of uh two to 4

play03:00

ton U house residential uh central air

play03:04

conditioning unit so this would not

play03:05

typically be appropriate for that kind

play03:07

of use uh but it would be appropriate if

play03:09

you wanted to use it for a window air

play03:11

conditioner or a floor air conditioner

play03:14

something like that now um you have a

play03:16

couple of options as I said you could

play03:18

you could use a standard generator cable

play03:19

which is usually these l1430 twist locks

play03:22

and actually that's what I've got there

play03:24

that's what I've got plugged into my

play03:25

manual transfer switch and it's got a uh

play03:28

a maale end on this side side here but

play03:30

before we do that we're going to check

play03:31

and make sure we're actually getting 240

play03:34

volts out of both of these ports um now

play03:36

if you wanted to use the

play03:38

l450 to connect to an l1430 on your uh

play03:42

manual transfer switch

play03:44

well you can do that with a simple uh

play03:47

adapter like this where this would go

play03:49

into the manual transfer switch and then

play03:51

this would just this l450 end the dyer

play03:54

style plug would just Connect into there

play03:57

now since I happen to have a longer

play03:58

generator cable any anyway it actually

play04:01

came with my manual transfer switch up

play04:02

there I'm just going to use that rather

play04:04

than than this adapter I just picked

play04:06

this up so I'd have another option if I

play04:08

ever needed it and also to be able to

play04:10

show you that these things are out there

play04:11

and they're easy to find now um you do

play04:14

when you're setting up your manual

play04:15

transfer switch and by the way I I will

play04:17

leave a link to that video as well in

play04:18

the description below it's much easier

play04:21

to do than you might think uh although

play04:23

check with code in your area to make

play04:24

sure it's not required that you use a

play04:26

licensed electrician for that or that a

play04:28

inspection is not uh required but it's

play04:31

always recommended even if it's not

play04:32

required have it inspected make sure you

play04:34

didn't violate any codes things like

play04:36

that because you do not want to burn

play04:37

down your house or injure yourself or

play04:39

anybody that you care about so all that

play04:42

uh disclaimer aside yeah you do want to

play04:44

make sure you get your circuits

play04:46

relatively balanced off of the two 120

play04:49

volt legs that are coming into your

play04:51

residential service I know I have some

play04:52

viewers in Australia and you guys are

play04:54

running off of 240 so this is different

play04:57

for you this is uh applicable to here in

play05:00

the US uh but you do want to make sure

play05:02

that your circuits are relatively evenly

play05:04

distributed in terms of load across

play05:06

those two legs and that's especially

play05:08

important when you're using split phase

play05:10

240 where you have two units two

play05:12

separate AC inverters up giving you the

play05:15

the power for those two legs because if

play05:17

you have them imbalanced it will drain

play05:20

the capacity of one faster than the

play05:21

other and then it's the lowest common

play05:23

denominator the one that runs out first

play05:25

the whole thing is going to shut down

play05:26

since it's in 240 240 mode so just be

play05:29

aware that you can add expansion

play05:31

batteries but uh you wouldn't want to

play05:33

add one expansion battery to this with

play05:35

two units you'd want to add two so both

play05:37

of these units had the same capacity to

play05:39

draw from so just be aware of that or

play05:41

you could add two expansion batteries

play05:44

and uh two to each one so total of four

play05:47

if you really wanted to go nuts with

play05:48

this now by themselves they have uh I

play05:51

think they the capacity is 3,420 W hours

play05:54

I believe so you have almost 7,000 wat

play05:57

hours of capacity which just two two of

play05:59

these main DBS 3500s and then combined

play06:02

it will give you a maximum 240 volt

play06:05

service of up to 7,000 Watts uh actually

play06:08

probably 7200 Watts because you're

play06:09

getting 3600 watts each uh unit all

play06:13

right let me get my multimeter here and

play06:14

let's uh let's test the output and make

play06:16

sure we are actually getting 240 volts

play06:19

make sure I'm in AC

play06:21

mode

play06:23

oh use your error you actually do have

play06:26

to turn on the AC inverters just because

play06:28

it came up like this it's ready to to

play06:30

start the timing but you have to turn on

play06:32

the AC inverter for both

play06:38

units there heard both relays kick on we

play06:41

should be good to go now let me check

play06:42

the voltage there we are

play06:46

238.9

play06:47

volts so we're getting our 240 volts let

play06:51

me go ahead and plug

play06:52

in my manual transfer switch I'm going

play06:55

to use the l1430

play06:57

connector since I can only get 30 amps

play07:00

anyway all right and I do have there's a

play07:02

little red light a little red LED on

play07:04

here by the way that tells you that this

play07:06

thing is

play07:07

live right now I can switch over my

play07:10

loads up here so I'll start with my hot

play07:13

water heater and uh let's just go ahead

play07:16

and start loading this

play07:22

up all right so I pretty much put this

play07:24

entire subpanel or at least the 10

play07:27

circuits that I have mapped over here

play07:29

onto this this and I don't have a lot

play07:30

running right now so I'm only pulling

play07:33

137 Watts let me see if I can get the uh

play07:37

hot water heater kick on make sure we

play07:39

can run

play07:41

that all right I'm running some hot

play07:43

water to kick my hot water heater on

play07:44

here hopefully here in just a little bit

play07:46

but this is a an example here one of my

play07:48

legs uh off of one of the phases of that

play07:51

240 volt I'm pulling 138 Watts so pretty

play07:55

small load but I'm not pulling anything

play07:57

off the other side right now on all the

play07:59

circuits that I've flipped over now

play08:00

that's going to change in just a little

play08:02

bit once the hot water heater kicks on

play08:04

but this kind of illustrates why it's

play08:06

important to make sure that you're

play08:07

relatively balanced otherwise like I

play08:09

said you'll drain one of the units

play08:10

faster than you drain the other and then

play08:13

whichever one drains uh empty first or

play08:15

goes to the low state of charge first

play08:16

and has to shut down it's all shut down

play08:19

so just be aware of that by the way this

play08:21

is absolutely plenty of power to be able

play08:24

to run your furnace in the winter time

play08:26

if you just need heat if you have a gas

play08:28

or propane furnace this will definitely

play08:31

handle that because that actually runs

play08:32

off of 120 and those typically pull

play08:34

about uh somewhere between 600 to 700

play08:37

Watts when they when they run it's

play08:38

mostly the blower that is consuming that

play08:41

power and then some of the other

play08:42

electronics around that but definitely

play08:44

possible to power furnace uh with one of

play08:46

these at least a gas furnace if you

play08:48

happen to have electric heat in your

play08:50

house you have a sense for how much uh

play08:51

how much watt power that actually draws

play08:54

I'd be curious to know I'm guessing it's

play08:56

going to be quite a bit more than 7,000

play08:58

Watts uh but I don't have electric heat

play09:00

so I'm not really quite sure how much

play09:02

those actually draw I'm just guessing

play09:04

it's a lot more than this so as you can

play09:06

see and possibly here the uh big

play09:09

electric water heater here to my left uh

play09:11

is actually running now we are pulling

play09:13

2800 watts here on this one and uh 2600

play09:17

Watts here on this one while I was off

play09:19

camera my my sewage pump actually kicked

play09:22

on because I was running a bunch of hot

play09:23

water down here in the downstairs

play09:25

basement and this bottom one spiked up

play09:27

to 3900 Watts for just about 3 or 4

play09:31

seconds as the pump ran and then it went

play09:33

back down and there it goes right

play09:36

there so we are at temporarily it spun

play09:39

up to 3900 Watts but it did not shut the

play09:43

system down it was able to handle that

play09:45

pump surge while the electric water

play09:47

heater was also running now one thing to

play09:50

keep in mind when it is actually

play09:51

providing AC power in Split phase mode

play09:54

you cannot recharge it via AC you can

play09:57

only recharge it via DC so that's kind

play10:00

of an important thing to be aware of so

play10:03

if you're going to be using this long

play10:04

term you need to be prepared to recharge

play10:07

it uh in a power an extended power AIO

play10:09

situation you need to be prepared to

play10:11

recharge these things via solar uh or

play10:14

some other DC input in order to recharge

play10:16

them not via AC because you'd have to

play10:19

disconnect them in order to uh recharge

play10:21

them in AC mode which you could

play10:22

certainly do uh but you have to take

play10:25

these uh take this little uh parallel

play10:27

junction box and disconnect connected in

play10:29

order to do that so just be aware there

play10:31

is that limitation but I do find this to

play10:34

be an extremely capable Budget Home

play10:36

backup power system uh despite its

play10:39

actual budget price and I've been very

play10:41

happy and and really delightfully

play10:43

surprised at how this unit performs in

play10:45

the four plus months that I've had it

play10:48

just uh seems to tick all the boxes yeah

play10:50

so I'll put information in the video

play10:52

description below if you want to go

play10:53

check it out and I do highly recommend

play10:55

you check out the video that I did it

play10:56

was a little bit longer format on on the

play10:58

single unit with an expansion battery

play11:00

just so you get a better sense of what

play11:01

the specs are uh but highly recommend

play11:03

checking that out and the links I've got

play11:05

for you in the description below so hey

play11:07

if you found anything of use uh or you

play11:09

learned anything in the video you found

play11:11

interesting please consider giving me a

play11:12

thumbs up on it I'd very much appreciate

play11:14

that and I do thank you for joining me

play11:16

for this video I do hope to see you in

play11:18

the next one as well until then have fun

play11:20

out there

play11:24

[Laughter]

play11:29

h

Rate This

5.0 / 5 (0 votes)

Related Tags
备用电源家庭应急电力系统Dobson DBS 3500分相输出便携式电源电力扩展太阳能充电家庭安全电力管理
Do you need a summary in English?