TLDRThis video script offers an insightful tour of a containment laboratory designed to control pathogens. It highlights the use of directional airflow and pressure control as key engineering controls in biorisk management. The walkthrough begins in an airlock with positive pressure, acting as an air curtain to prevent pathogens from escaping. It then moves to a negative pressure zone where air is filtered through a high-efficiency particulate filter before release. The script explains the progressive decrease in pressure as one moves deeper into the lab, ensuring pathogens are confined to specific areas. The tour concludes with an overview of how these engineering controls are applied to contain microbes within designated laboratory spaces.
Takeaways
- 🛡️ Containment labs use directional airflow to manage pathogens within a confined space.
- 🔒 The airlock maintains positive pressure to prevent outside air from entering and potentially contaminating the area.
- 💨 Positive pressure acts similarly to an air curtain at a supermarket entrance, keeping pathogens contained.
- 🔄 Negative pressure zones are created to ensure that air enters the zone but is filtered before being released into the environment.
- 🕳️ High-efficiency particulate filters with a 0.22 micron size effectively trap pathogens and particulates.
- 🌐 The directional airflow in the lab decreases as one moves deeper into the containment areas.
- 🔽 Negative pressure zones direct air towards filters in the ceiling, ensuring that it is filtered through HEPA filters before exiting.
- 🧪 All work involving pathogens, such as diagnostics and experiments, is conducted in the negative pressure suites.
- 🏢 Engineering controls based on directional airflow are a fundamental component of biological safety laboratories.
- 🚫 The purpose of these controls is to confine microbes to their respective laboratories and working areas to prevent spread.
- 🙏 The script concludes with a thank you for watching, emphasizing the educational intent of the video.
Q & A
What is the primary concept of containment in a laboratory setting?
-The primary concept of containment in a laboratory setting is the use of directional airflow to control the spread of a pathogen within a confined space.
What is an airlock in a laboratory and what is its purpose?
-An airlock in a laboratory is a region where positive pressure is maintained. Its purpose is to keep air from the external environment and other areas of the lab from entering, thus preventing the spread of pathogens.
How does positive pressure in an airlock prevent the spread of pathogens?
-Positive pressure in an airlock prevents the spread of pathogens by creating a barrier that keeps air from entering from either side, similar to an air curtain at a supermarket entrance.
What is the role of negative pressure in a laboratory zone?
-Negative pressure in a laboratory zone ensures that air enters the zone but is filtered through a high-efficiency particulate filter before being released into the environment, trapping most pathogens.
What is the purpose of a high-efficiency particulate filter in a laboratory?
-A high-efficiency particulate filter is used to filter out most pathogens by trapping them in a matrix. It has a size of 0.22 microns, which is effective in trapping all pathogens and particulates.
How does a negative pressure zone direct air flow in a laboratory?
-In a negative pressure zone, the air is directed towards filters located in the ceiling. It flows through the ceiling and a HEPA filter before exiting into the external environment.
What is referred to as an engineering control in biorisk management?
-An engineering control in biorisk management refers to the use of directional airflow and negative pressure zones to prevent the spread of pathogens, ensuring that they are confined to specific areas of the laboratory.
How does directional airflow continue to change as one progresses into the laboratory?
-As one progresses into the laboratory, the directional airflow continues to drop, with the pressure becoming more negative in the suites or laboratories where work involving pathogens takes place.
What is the purpose of having a progressively lower negative pressure zone in a laboratory?
-The purpose of having a progressively lower negative pressure zone is to confine pathogens to specific areas of the laboratory, ensuring that all work involving pathogens, such as diagnostics and experiments, is safely contained.
How does the concept of containment apply to the engineering controls at the facility?
-The concept of containment applies to the engineering controls at the facility by using negative pressure zones and directional airflow to confine microbes to their respective laboratories and working areas.
What is the significance of the containment concept in a biological safety laboratory?
-The containment concept is significant in a biological safety laboratory as it ensures the safe handling and study of pathogens by preventing their spread to other areas and the external environment.
Outlines
🛡️ Containment Laboratory Concept
This paragraph introduces the concept of a containment laboratory which uses directional airflow to control and confine pathogens within a specific space. The narrator is in an airlock, a region with positive pressure that prevents air from entering or leaving, acting like an air curtain at a supermarket entrance. The purpose is to keep pathogens confined and secure.
Mindmap
Keywords
💡Contained laboratory
💡Directional airflow
💡Airlock
💡Positive pressure
💡Negative pressure
💡High-efficiency particulate filter (HEPA filter)
💡Engineering controls
💡Biorisk management
💡Pathogens
💡Diagnostics and experiments
Highlights
A contained laboratory uses directional airflow to control a pathogen within a confined space.
The concept of containment is crucial for managing pathogens.
An airlock is a region in the laboratory with positive pressure to prevent outside air from entering.
Positive pressure in the airlock acts like an air curtain at a supermarket entrance.
Negative pressure zones are maintained to ensure air enters but is filtered before release.
High-efficiency particulate filters with 0.22 micron size trap pathogens.
Negative pressure directs air towards filters located in the ceiling.
Air flows through HEPA filters before exiting into the external environment.
Engineering controls based on directional airflow are a common component in biological safety laboratories.
Pressure continues to drop as one moves into the laboratory to confine pathogens.
Work involving pathogens, such as diagnostics and experiments, takes place in negative pressure suites.
Engineering controls are applied to contain microbes to their respective laboratories and working areas.
The basic concept of containment is to manage and control the spread of pathogens.
Directional airflow and pressure control are key to the containment of microbes.
Laboratories are designed with a stepwise decrease in pressure to effectively contain pathogens.
The video provides an overview of the engineering controls used in a containment facility.
Thank you for watching, highlighting the importance of understanding containment concepts.
Transcripts
to begin with
a contained laboratory
uses directional airflow to control
a pathogen within a confined space
this is the primary concept of
containment
i am now in what is known as an
airlock so this is basically
a region in the laboratory in which we
have positive pressure
positive pressure basically keeps
any air out from this area
on either side so if you look on this
side
if you follow the video this is the
external environment
and we look on this side and this side
is
the basically the
area which is under containment now this
area
can be compared to an air curtain at a
supermarket
entrance the air basically is a
downdraft
which locks in the pathogen
in the containment zone i will now
proceed
to the next
zone so the next zone is
maintained at a negative pressure
this negative pressure ensures that air
will enter into this zone
however when it is filtered out for
release into the environment
it will be passed through a high
efficiency particulate filter
this filter will filter out most of the
pathogens
by trapping them in a matrix
basically the filter has 0.22 micron
size so essentially
all pathogens and particulates are
trapped in the filter
now this zone is at negative pressure
in a negative pressure zone the air is
directed
towards filters which are located in the
ceiling so the air
flows through this through the ceiling
through a hepa filter
before it exits into the external
environment
this is referred to in biorisk
management
as an engineering control engineering
controls based on directional airflow
are a common component in all biological
safety laboratories
so as we progress to the laboratory the
directional
airflow will continue
to drop for example we have entered at
this location
and the pressure is negative here so as
i proceed
into the suites or the laboratories
areas
the pressure will keep dropping to a
lower and lower negative
pressure zone this is the way in which
pathogens are confined
to this region of the laboratory
so all the work involving pathogens such
as diagnostics and experiments
takes place in these three suites they
are
under negative pressure as compared to
the zone
at which i am standing in right now
this is the way in which an engineering
control is applied
at this facility to contain microbes
to their respective
laboratories and working areas
this is the basic concept of containment
thank you very much for watching
Посмотреть больше похожих видео
Compressed Air Line In Ship-Main air, service air,control air system in Engine Room
Climate and weather | Global air circulation | Grade 12 Geography INTRODUCTION |Thundereduc|
Mecánica de fluidos primera parte
Pneumatic Cylinder: How Does It Work?
Water Potential
How does Aircraft generates lift? Bernoulli's principle
5.0 / 5 (0 votes)