how to use a triple beam balance

MisterHager
15 Sept 201106:00

Summary

TLDRThis video provides a comprehensive guide on how to use a triple beam balance for measuring mass. It explains the different parts of the balance, including the pan, beam, zero marker, and the riders that measure in increments of 100g, 10g, and 0.1g. The video demonstrates three key methods: directly measuring the mass of an object, finding mass by difference (for liquids), and measuring a specific amount of a substance, such as chemicals. The importance of careful adjustments and proper technique is emphasized to ensure accurate measurements.

Takeaways

  • 😀 The triple beam balance is a tool used to measure mass with components like the pan, beam, zero marker, and riders.
  • 😀 The largest rider measures in 100g increments, the medium rider in 10g increments, and the smallest one measures in tenths of a gram.
  • 😀 Always ensure the balance's riders are zeroed before starting any measurement, with the zero marker also at zero.
  • 😀 To measure mass directly, place the object on the pan and adjust the riders until the pointer is balanced at zero.
  • 😀 Start with the middle rider (100g), then move to the 10g rider, and finally adjust the smallest rider to achieve precise balance.
  • 😀 When measuring liquids or fluids, first measure the mass of the container, then add the liquid and subtract the container's mass to find the liquid's mass.
  • 😀 For mass measurement by difference, use the balance to find the mass of the container first, and then add the liquid or substance.
  • 😀 When weighing a solid chemical, use weighing paper or a container to avoid placing chemicals directly on the pan.
  • 😀 Carefully add chemicals to the weighing paper and adjust the smallest rider to ensure accurate mass measurement.
  • 😀 Always add substances slowly to avoid overshooting the desired mass, ensuring accuracy in measurements.

Q & A

  • What is the purpose of using a triple beam balance?

    -The triple beam balance is used to measure the mass of objects with precision. It helps determine the exact weight by adjusting the position of the riders on the beam.

  • What are the main components of a triple beam balance?

    -A triple beam balance consists of a pan, a beam, a zero marker, and three riders that measure in different increments: 100g, 10g, and 0.1g.

  • How do you ensure the triple beam balance is set to zero before use?

    -Before using the balance, make sure all the riders are pointing to zero and the zero marker is resting at zero. This ensures accurate measurements.

  • What is the correct procedure for measuring the mass of an object using a triple beam balance?

    -To measure mass, place the object on the pan, then adjust the riders, starting with the largest (100g), followed by the 10g, and finally the 0.1g, until the pointer is balanced at zero.

  • Why is it important to start with the 100g rider when measuring mass?

    -Starting with the 100g rider ensures that you quickly find the closest value for the object's mass. This helps minimize adjustments needed with the smaller riders.

  • How do you measure the mass of a liquid or fluid using a triple beam balance?

    -To measure the mass of a liquid, first measure the mass of the empty container. Then, pour the liquid into the container and adjust the riders again to find the mass of the container with liquid. Subtract the mass of the container to get the liquid's mass.

  • Why can’t liquids be placed directly on the pan of the triple beam balance?

    -Liquids cannot be placed directly on the pan because they will spill or fly off. Instead, a container is used to hold the liquid for measurement.

  • What is the method for measuring the mass of a solid chemical using a triple beam balance?

    -To measure a solid chemical, first find the mass of the container or weighing paper. After that, slowly add the chemical to the container and adjust the riders to the desired mass.

  • How do you prevent adding too much substance when measuring a chemical?

    -When measuring a chemical, add it slowly and carefully adjust the riders. If you add too much, reset the balance and start again. Always go slowly to ensure accuracy.

  • What should you do if the pointer of the triple beam balance drops below zero during use?

    -If the pointer drops below zero, it indicates you've moved the rider too far. You should back up and readjust the riders until the pointer is balanced at zero.

Outlines

plate

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.

Améliorer maintenant

Mindmap

plate

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.

Améliorer maintenant

Keywords

plate

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.

Améliorer maintenant

Highlights

plate

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.

Améliorer maintenant

Transcripts

plate

Cette section est réservée aux utilisateurs payants. Améliorez votre compte pour accéder à cette section.

Améliorer maintenant
Rate This
★
★
★
★
★

5.0 / 5 (0 votes)

Étiquettes Connexes
Triple BeamMass MeasurementScience Education6th GradeSTEM LearningLab EquipmentMass AccuracyChemical MeasurementBalance TechniquesWeighing Procedures
Besoin d'un résumé en anglais ?