Como Funciona a Proteção de Sobrecorrente de Fase 50/51 ?! Como Parametrizar e Entender esse RELÉ?
Summary
TLDRThis video provides an in-depth explanation of protection relays, focusing on the 51 relay used for overcurrent protection in electrical systems. It covers how the relay functions based on a current-time curve, with settings adjusted for different protection needs. The importance of coordinating response times for short circuits and avoiding uncoordinated protection is emphasized. The video also touches on the selection of different relay types (51, 50) and the role of standards in network protection. Future topics include neutral-ground protection and advanced relay settings.
Takeaways
- 😀 The script discusses the concept of short circuit protection using time-current curves and relay settings.
- 😀 The relay's protection behavior depends on the time and current thresholds, with different actions for short circuits of varying severity.
- 😀 An instantaneous action is triggered for larger current values, such as 6,000 amps, while smaller currents result in delayed actions based on the curve.
- 😀 The time-current curve allows for flexibility in setting protection parameters to ensure the right response time for different fault conditions.
- 😀 The script highlights the importance of adjusting the relay parameters to balance protection speed and system reliability.
- 😀 Understanding and configuring the time-current curve is crucial for ensuring proper relay operation and avoiding unnecessary delays or failures.
- 😀 The relay's time-action coordination is essential in preventing system damage, particularly in industrial and feeder networks.
- 😀 A short circuit can be quickly protected against by setting the right current and time thresholds, with considerations for both instantaneous and delayed actions.
- 😀 The instructor refers to different protection philosophies and industry standards that influence relay configurations and network protection strategies.
- 😀 The script introduces future lessons on advanced topics like ground fault protection and directional relays, which further expand on protection concepts.
- 😀 Relay coordination plays a critical role in ensuring protection zones are correctly isolated during faults, preventing cascading failures in electrical networks.
Q & A
What is the primary focus of the video script?
-The video focuses on the protective relay 51, explaining its coordination with fault currents, response times, and how it works with different curves to protect electrical systems from short circuits and other faults.
What does the '51' relay signify in the script?
-The '51' relay refers to an overcurrent protection relay that responds to electrical faults based on preset current thresholds, with a time delay depending on the magnitude of the fault current.
How does the protection relay react to different fault currents?
-The relay reacts differently depending on the fault current. For higher fault currents, such as 6,000 amps, it responds instantaneously. For lower fault currents, it introduces a time delay based on the current and predefined settings.
What role does the characteristic curve play in the relay's operation?
-The characteristic curve determines how the relay responds to faults. It defines the time-delay behavior depending on the magnitude of the fault current, ensuring the protection relay operates efficiently and avoids unnecessary trips.
Why is the 'instantaneous' trip setting important?
-The instantaneous trip setting ensures the relay reacts immediately to very high fault currents (e.g., 6,000 amps), preventing damage to equipment or further system failures without waiting for a delay.
What happens when the fault current is between 5,000 and 6,000 amps?
-When the fault current is between 5,000 and 6,000 amps, the relay is set to delay its response. It may take several seconds (e.g., 0.3 seconds) to activate, providing protection without tripping too quickly.
What is the significance of the '50' setting in the relay?
-The '50' setting corresponds to the current value at which the relay begins to act. When set to 6,000 amps, the relay's secondary current will reach 50 amps, signaling the point at which protection should trigger.
How does relay coordination depend on network protection philosophy?
-Relay coordination depends on the network's protection philosophy, which considers factors like the system’s fault current, the type of protection needed, and whether the protection is designed for a radial or distributed network.
What are the key differences between instantaneous and time-delayed protection?
-Instantaneous protection trips immediately when the fault current exceeds the threshold, while time-delayed protection introduces a delay based on the fault current, allowing for coordination with other protective devices.
What will be discussed in the next class according to the speaker?
-In the next class, the speaker plans to discuss ground fault protection (neutral-ground), as well as directional protection and the differences in how the relay operates under these conditions.
Outlines

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.
Mejorar ahoraMindmap

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.
Mejorar ahoraKeywords

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.
Mejorar ahoraHighlights

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.
Mejorar ahoraTranscripts

Esta sección está disponible solo para usuarios con suscripción. Por favor, mejora tu plan para acceder a esta parte.
Mejorar ahoraVer Más Videos Relacionados

Littelfuse - MPU 32 & MPS Motor Protection Relays

(हिंदी में) - Part-1: Overcurrent & Earth Fault Protection || Over Current || Definite Time || IDMT

Penggunaan Media Pembelajaran Trainer Pengaman Arus Bocor Pada Instalasi Listrik Rumah Tinggal

Perbedaan dari tipe ke dua Smart Relay Zelio Schneider Electric #zelio #schneiderelectric #relay

Switch-Onto-Fault (SOTF) Scheme Basics | Example Using the SEL-411L Protective Relay

Co to jest i jak działa przekaźnik elektromagnetyczny w automatyce przemysłowej?
5.0 / 5 (0 votes)